General
|
Voltage Inputs
|
Phase A, B,C, Neutral, and Ground
|
Current Inputs
|
Phase A, B,C, and Neutra
|
Power Types
|
3-Phase Delta and Wye, 3-4 Wire, Split-phase, 3 Single
Phase
|
User Interface
|
Active TFT Display
|
10.44" Diagonal Color Screen 640 x 480 dpi With Touch
Screen Feature
|
Mini Keyboard
|
Qwerty
|
PC Software
|
PowerACE for Windows™
|
Operating Power
|
AC Voltage
|
80 - 230 VAC
|
DC Voltage
|
125 VDC - 250 VDC
|
Frequency
|
DC, 46 - 65 (400 Hz avbl. 2000)
|
Memory
|
Hard Drive
|
6.2 Gbyte IDE
|
Floppy Drive
|
1.44 Mbyte 3.5"
|
Measurement Range and Capability
|
Channels
|
4 Voltage / 4 Current
|
Voltge
|
5-750VAC, 0-800VDC, 1200VDC T<1Sec.
0.01 to 20000 PT Ratio
|
Input Type
|
Individually Isolated
|
Impedance
|
2 Megohm
|
Current
|
0 to 3 VAC/DC or 5A AC/DC (Optional)
0.01 to 10000 CT Ratio
|
Sample Rate 60 Hz
|
256 Samples/Cycles (15.5 KHz)
|
Sample Rate 50 Hz
|
256 Samples/Cycles (12.8 KHz)
|
Sample Rate 400 Hz
|
256 Samples/Cycles (51.2 KHz) (avbl.2000)
|
Sample Rate Peak Detector
|
1 MHz (4 MHz avbl. 2000)
|
Sample Rate 4 MHz*
|
10 MHz Configurable
|
Synchronization
|
CH1 Volt, CH1 Current or PLL
|
Max. Allowable
|
6 KVpk +/-0.2% Full Scale
|
Mesurement Accuracy
|
Voltage
|
+/-0.05% Full Scale
|
Current
|
+/-0.05% Full Scale
|
Fast Transient
|
1u SEC, 1% Full Scale
|
Resolution
|
14 Bit
|
Environmental
|
|
Enclosure
|
Rain, Dust, ICE, Dorrosion and Flame Resistant V-O
|
Operation Temperature
|
-30 to 55 Degrees C
(-22 to 131 Degrees F)
|
Operating Humidity
|
0 to 98% Non-Condensing
|
Physical
|
|
Dimensions
|
470mm × 470mm ×24mm
(Height × Width ×Depth)
|
Weight
|
9 kg (20 LBS)
|
Measurement Capability
|
Voltage & Current
|
RMS; Min, Max, Avg on All
Measurements (Configurable), Waveforms
|
Power Quality
|
Waveshape Faults, Snapshots, RMS Summaries and Variations,
Frequency, Demand
|
Power Flow
|
Watts, Active, Apparent, Reactive, Power Factor
|
Energy/Demand
|
Active, Apparent, Reactive, Thermal Demand
|
Unbalance
|
Voltage
|
Harmonics
|
DC, the Up to 63rd Order, Voltage, Current, Power
|
Transient Capture
|
1MHz Peak Detector
(*4MHz Peak Detector avbl. 2000)
|
Flicker
|
According to IEC 868, IEC 61000-4-15
|
PowerACE for Windows™
|
Compatibility
|
WindowsTM 95, 98, NT
|
Quick Setup
|
Fully Automatic or Selection of Predefined Setups
|
Advanced Setup
|
Full Setup Customization
|
Real Time
|
All Measurements Including Text, Waveforms, Spectra, Phasors
|
Survey Analysis
|
Time Plots, Summaries, Text, Waveforms, Spectra, Phasors,
Flicker CPF
|
Cbema Plot
|
Yes (avbl. 2000)
|
Data Download
|
Full or By Event.
|
Automatic Survey Report
|
Report Generation into
MS Word 6.0/7.0, Data Export in ASCII-CSV Format.
Summary and Text Reports
|
Communications
|
Ethernet
|
TCP/IP 10 Base T, BNC, RJ45
(Twisted Pair and Coax)
|
Modem
|
56 Kbps, ISDN*
|
Serial
|
RS232, RS485* (115 KBAUD)
|
Parallel
|
Centronics
|
Internet/Intranet
|
Through Isp
|
Infrared (for ACE Quatro)
|
Short Distance (1 M/9600 BAUD) (3'/9600 BAUD),
Long Distance (10 M/1200 BAUD) (30'/1200 BAUD)
|
Recorder
|
Activation
|
Continuous, or By Exception, External and Internal, Clock
Time
|
Rate
|
1 Cycle - 1 Week or 1-10,000 Cycles, Multiple Rates for
Continuous and On-Trigger Recording.
Configurable Synchronization
|
Triggers
|
Voltage and Current, Internal, External, Manual, Up to
32 On any Measurement, PRE-Trigger 1 Sec., Post-Trigger Unlimited.
|